摘要
针对高压变压器通用微机保护装置频频出现TA断线、TA饱和检测、启动元件等问题,对高压配电装置微机保护器进行合理优化。通过硬件电路设计和软件设计,使系统的工作效率大大提升,减少了人为的误操作,从而提升了系统可靠性和安全性。
Aiming at the problems of TA breakage,TA saturation detection,startup element and so on,the microcomputer protector of high voltage transformer is optimized reasonably.Through the design of hardware circuit and software,the working efficiency of the system is greatly improved,the artificial misoperation is reduced,and the reliability and safety of the system are improved.
作者
樊哲
Fan Zhe(Tongfa Zhoudongyao Coal Industry Co.,Ltd.of Datong Coal Mine Group,Datong Shanxi 037000)
出处
《机械管理开发》
2019年第1期194-195,250,共3页
Mechanical Management and Development
关键词
井下
高压配电装置
微机综合保护器
downhole
high voltage distribution device
microcomputer integrated protector