摘要 对直径为1 400mm的大型复杂钛合金机匣进行渗透检测时,使用静电喷涂法施加渗透液,可使渗透液覆盖机匣全表面,无多余渗透液淤积,清洗时间减少,背景良好,缺陷显示结果可靠。检测中结合黑光光源,使用工业内窥镜可以拓宽渗透检测过程中人眼目视可达的区域范围。选择工业内窥镜探头时,应根据腔体大小及缺陷部位,保证测量光照条件(与待检表面距离合适),才能得到较清晰的缺陷显示,从而提高判定的准确性与可靠性。 For the penetrant inspection of large titanium ally casing with a diameter of 1 400 mm,the electronic spraying method can make the penetrant cover the entire surface with unnecessary liquid penetrant deposition.This method reduces the cleaning time,obtains an acceptable background and reliable defect indications.Combining black light source with industrial endoscopy can widen the reachable area of human vision in the process of penetration detection.The selection of the industrial endoscope lens used in the inspection should be based on the cavity size,the defects location and the proper lighting conditions(with suitable distance apart from the surface to be inspected)in order to obtain the clearer indication of defects and improve the accuracy and reliability of the judgment.
作者 乔海燕 赵宏达 任学冬 王树志 高文博 QIAO Haiyan;ZHAO Hongda;REN Xuedong;WANG Shuzhi;GAO Wenbo(AECC Beijing Institute of Aeronautical Materials,Beijing 100095,China;Beijing Key Laboratory of Aeronautical Materials Testing and Evaluation,Beijing 100095 ,China;Key Laboratory of Aeronautical Materials Testing and Evaluation,Aero Engine Corporation of China,Beijing 100095 ,China)
出处 《无损检测》 2019年第1期9-13,共5页 Nondestructive Testing
关键词 大型复杂钛合金机匣 渗透检测 静电喷涂 工业内窥镜 可靠性 large complex titanium ally casing penetrant testing the electronic spraying industrial endoscope reliability
  • 相关文献

参考文献5

二级参考文献84

共引文献371

同被引文献13

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部