期刊文献+

含氟碳气体的表面活性剂类声学造影剂的体外实验 被引量:3

Ultrasound Contrast Agent of Surfactant Fluorocarbon-Filled in Vitro
下载PDF
导出
摘要 目的 研究含氟碳气体的表面活性剂类声学造影剂的基本特性。方法 将具有表面活性作用的司班 -80 和吐温 -80 按一定的体积比配制 ,加入 6 %低分子右旋糖酐溶液至 10ml,并将混合液充分搅拌 ;用声振仪振荡混合液 40s ,同时从注射器的底部匀速注入 10ml全氟丙烷气体。光镜 40 0倍下动态观察微气泡的浓度和直径 ,并运用体外循环系统观察不同剂量的彩色多普勒信号增强效果。结果 造影剂中微气泡的峰值浓度为 3.8× 10 9/ml,其中 90 %微气泡直径≤ 4.5 μm。体外模拟循环系统的能量多普勒信号增强持续时间随剂量增加而增加。结论 表面活性剂类声学造影剂的微气泡直径小、浓度高 ,且具有价格低廉、制作简单和明显增强多普勒信号的特点 。 Objective The basic characteristics of ultrasound contrast agent of surfactant fluorocarbon filled were studied. Methods Six percent dextrose was put in the mixture consisted of span -80 and tween -80 of the surfactant in proportion up to 10ml. Then it was sonicated for 40 seconds by sonicator, meanwhile in which 10ml perfluoropropane gas was injected. The concentration and size of the microbubbles was measured on a ×400 field of microscope. The effect of color Doppler signal were measured in extracorporeal circulative system after different dosage of contrast agent was injected. Results The peak concentration of contrast agent microbubble was 3.8×10 9/ml,90% size of microbubble ≤4.5μm. The persistence of color Doppler signals in extracorporeal circulative system increased with increasing the dosage. Conclusion The characteristics of surfactant contrast agent are small size, high concentration, cheap price, simple manufacture and obvious enhancement of Doppler signal. It would be researched further.
出处 《中国医学影像技术》 CSCD 2002年第2期99-101,共3页 Chinese Journal of Medical Imaging Technology
基金 军队医药卫生科研基金资助 (0 0J0 2 )
关键词 超声 表面活性剂 声学造影剂 含氟-碳气体 Ultrasound Surfactant Contrast agent
  • 相关文献

参考文献9

  • 1唐杰,董宝玮,于晓玲,罗渝昆,程志刚,刘海一,唐龙,崔屹.图像处理系统辅助肝脏超声造影测定[J].中华超声影像学杂志,1999,8(4):206-209. 被引量:5
  • 2Porter TR,Xie F,Kricsfeld A,et al.Myocardial perfusion abnormaltities during low-dose dobutamine after coronary reperfusion can be demonstrated with intravenous perfluorocarbon-exposed sonicated dextrose albumin ultrsound contrast[J].Am Heart J,1996,131:1079-1087.
  • 3Basude R,Duckworth JW,Wheatley MA.Influence of environmental conditions on a new surfactant-based contrast agent: ST68[J].Ultrasound in Med & Biol,2000,26:621-628.
  • 4Gramiak R,Shah PM.Echocardiography of the aortic root[J].Invest Radiol,1968,3:356-366.
  • 5Goldberg BB,Liu JB,Forsberg F.Ultrasound contrast agents: A review[J].Ultrasound in Med & Biol,1994,20:319-333.
  • 6Forsberg F,Liu JB,Merton DA,et al.Parenchymal enhancement and tumor visualization using a new sonographic contrast agent[J].J Ultrasound Med,1995,14:949-957.
  • 7Schneider M,Arditi M,Barrau MB,et al.A new ultrasonographic contrast agent based on sulfur hexafluoride-filled microbubbles[J].Invest Radiol,1995,30(8):451-457.
  • 8Correas JM,Burns PN,Lai XM,et al.Infusion versus bolus of an ultrasound contrast agent: In vivo dose-response measurements of BRl[J].Inveat Radiol,2000,35(1):72-79.
  • 9杨耀琴,杨虎川,陶惠红,朴文姬,杜逸峰.吐温80合并温热对小鼠实体瘤及腹腔主要脏器结构的影响[J].中华物理医学杂志,1997,19(3):129-132. 被引量:8

二级参考文献7

共引文献11

同被引文献17

  • 1Brown MA,Casola G,Sirlin CB,et al.Importance of evaluating organ parenchyma during screening abdominal ultrasonography after blunt trauma.J Ultrasound Med,2001,20:577-583
  • 2Liu JB,Merton DA,Goldberg BB,et al.Contrast-enhanced two- and three-dimensional sonography for evaluation of intra-abdominal hemorrhage.J Ultrasound Med,2002,21:161-169
  • 3Phillips P,Gardner E.Contrast-agent detection and quantification.Eur Radiol,2004,14 Suppl 8:4-10
  • 4Maruyama H,Matsutani S,Saisho H,et al.Grey-scale contrast enhancement in rabbit liver with DMP115 at different acoustic power levels.Ultrasound Med Biol,2000,26:1 429-1 438
  • 5Seidel G,Meyer K,Algermissen C,et al.Harmonic imaging of the brain parenchyma using a perfluorobutane-containing ultrasound contrast agent.Ultrasound Med Biol,2001,27:915-918
  • 6Bos LJ,Piek JJ,Spaan JA.Effects of shadowing on the timeintensity curves in contrast echocardiography:a phantom study.Ultrasound Med Biol,1996,22:217-227
  • 7Moore EE,Cogbill TH,Jurkovich GJ,et al.Organ jnjury scaling:spleen and liver (1994 revison).J Trauma,1995,38:323-324.
  • 8Benya EC,Lim-Dunham JE,Landrum O,et al.Abdominal sonography in examination of children with blunt abdominal trauma.Am J Roentgenol,2000,174:1613 1616.
  • 9McKenney M,Lentz K,Nunez D,et al.Can ultrasound replace diagnostic peritoneal lavage in the assessment of blunt trauma?J Trauma,1994,37:439-441.
  • 10Richards JR,Schleper NH,Woo BD,et al.Sonographic assessment of blunt abdominal trauma:a 4-year prospective study.J Clin Ultrasound,2002,30:59-67.

引证文献3

二级引证文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部