期刊文献+

盾构隧道管片接头抗弯刚度的经验公式 被引量:27

Empirical formula for bending stiffness of shield tunnel segment joint
下载PDF
导出
摘要 接缝抗弯刚度是装配式衬砌结构设计的重要参数,工程中一般是通过接头的荷载试验来确定。文章以某拟建大型水工盾构隧洞的管片接头荷载试验为基础,简要介绍了装配式管片接头荷载的试验方法、影响接头刚度的各种因素及其影响规律。通过对试验数据的分析,建立了管片接头抗弯刚度的经验公式,给出了不同偏心距的接头抗弯刚度系数的变化范围。 Bending stiffness of segment joint is a important parameter in shield tunnel structure design. In most cases , the bending stiffness of segment joint is given by joint load test. This paper deals with the method of the seg-mental joint load test, and the factors affecting the bending stiffness is also discussed. Based on the results from joint load test, the empirical formula of bending stiffness of the segmental joint is developed, the range of bending stiffness of joint with different eccentricity is given.
出处 《现代隧道技术》 EI 2002年第2期12-16,52,共6页 Modern Tunnelling Technology
关键词 盾构隧道 抗弯刚度 经验公式 装配式衬砌结构 管片接头 水工隧洞 Shield driven tunnel Segmental lining Joint bending stiffness Empirical formula
  • 相关文献

参考文献6

  • 1佐久間彰三 石田智郎.一次覆工,二次覆工間のせん断特性を考虙したシ一ルドトンネルの軸剛性評価[J].土木学会論文集,1990,424:251-259.
  • 2Nobuyuki Takamatsu. A Study on the bending behavior in the longitudital direction of shield tunnels with secondary linings. Towards New Worlds in Tunnelling, 1992 Balkema, Rotterdam
  • 3朱合华,陶履彬.盾构隧道衬砌结构受力分析的梁-弹簧系统模型[J].岩土力学,1998,19(2):26-32. 被引量:116
  • 4村上博智,小泉.シ一ルドセゲメントリンゲの耐荷機構について.土木学会論文報告集,1978,No.150:103-115
  • 5Nasri A. Munfah & Michael P. Della Posta. Full scale testing of tunnel liner. Towards New Worlds in Tunnelling, 1992 Balkema, Rotterdam
  • 6陆同寿 崔铁军.圆形衬砌接头刚度模型试验与研究[J].隧道及地下工程,1987,8.

二级参考文献1

  • 1刘建航,盾构法隧道,1991年,75页

共引文献121

同被引文献190

引证文献27

二级引证文献276

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部