摘要
建立了快速测定硫酸铬中铬 含量的分光光度法。以EDTA作铬 的掩蔽剂 ,测定时无需进行分离。铬 在 0~2 5 μg/mL范围内呈线性关系 ,相关系数r=0 9992 ,检出限 0 0 2 μg/mL ,回收率 95 2 %~ 10 4 3 % ,RSD≤ 2 7%。方法简单。
A spectrophotometric method for direct determination of Cr*& in chromium sulfate has been proposed Selecting EDTA to mask Cr*#, Cr*& is not necessary to be separated for the determination The linear range was 0-25μg/mL for Cr*& with correlation coefficient(r) 0 9992 The limit of detection was 0 02μg/mL,the recovery was 95 2%-104 3%,and RSD≤2 7% The method is rapid and easy to operate
出处
《冶金分析》
CAS
CSCD
北大核心
2002年第1期61-63,共3页
Metallurgical Analysis