期刊文献+

沸石去除污水中氨氮的研究 被引量:32

Research on Removing Ammonia-Nitrogen from Wastewater by Actived Zeolite
下载PDF
导出
摘要 通过室内试验证明 :活化沸石是一种良好的除氨材料 ,交换容量可达 1.4 5mg/ g沸石 ,能够用于污水除氨 ;影响活化沸石除氨的主要因素是滤料的装填高度、滤速、沸石粒径大小、原水水质以及沸石运行过程的生物相形成等 .建议滤柱较佳工作条件为 :滤料粒径 0 .8~ 1.7mm ,滤料装填高度 1.2m ,运行滤速 3~ 4m/h . The tests in lab has proved that actived zeolite is an available material, and its exchange capacity can reach 1.45mg/g,and be used to remove ammonia-nitrogen from wastewater. The influence of zeolite size, filter velocity, zeolite height and bacteriain in the filter process on removing nitrogen has been discussed too. The optimal working condition are size of zeolite 0.8~1;7mm; column height 1.2m; filter velocity 4m/h.
作者 肖举强
出处 《兰州铁道学院学报》 2002年第1期87-89,共3页 Journal of Lanzhou Railway University
关键词 沸石 氨氮 过滤 污水处理 除氨 wastewater actived zeolite ammonia filter removing