触诊在乳腺摄片中的作用探讨 被引量:1

The Value of Palpate in Mammography
下载PDF
导出
摘要 目的:探讨摄片前触诊的价值及作用。方法:乳腺包块分别由临床及摄片前触诊。结果:311例乳房包块患者,198例临床及摄片前触及包块,113例仅患者自触有“包块”。讨论:(1)触及乳房包块时应注意月经情况,尽可能在月经后三日复查摄片;(2)摄片前的触诊能减少多余X线照射且不影响诊断;(3)摄片前触诊常能避免副乳的漏检;(4)触诊引导包块活检可提高诊断的准确性;(5)摄片前触诊时的挤压可发现乳头溢液。 Objective: To evaluate the value of palpate before mammography. method: Mammary mass was palpated by gynecoloist and radiologist respectively. Result: In 311 patients, 198 cases were confined by gynecoloist and radiologist before mammo graphy, other 113 cases were confined by patient themselves. Conclusion: (1) Pay attention to menacne when mammary mass was palpated, re - mammography was necessary in the third day after menacne; (2) Palpate before mammography can decrease radiaolesion; (3) Palpate before mammography can decrease misdiagnosis of accessory mamma; (4) The accuracy of diagnosis was increased by palpate - guided biospy ; (5) The mammillary fluid can be found by palpate.
出处 《成都医药》 2000年第1期25-26,共2页
关键词 触诊 乳腺 乳房色块 X线诊断 乳腺摄片 乳腺疾病 palpate mammography mamma mass
  • 相关文献

参考文献2

共引文献8

同被引文献32

  • 1汤荣光.正常人足底静态和动态压力分布的测定[J].中国生物医学工程学报,1994,13(2):175-177. 被引量:32
  • 2邓辉胜,黄晶,郑永平,邓昌明,刘地川,李进嵩,王志刚.介入超声印压检测活体心肌硬度的实验研究[J].中国超声医学杂志,2007,23(3):164-166. 被引量:6
  • 3Mahoney L, Csima A. Efficiency of palpation in clinical detection of breast cancer [J]. Can Med Assoc J,1982,127(8):729-730.
  • 4Davis AM, Dische S, Gerber L, et al. Measuring postirradiation subcutaneous soft-tissue fibrosis:state-of-the-art and future directions [J].Semin Radiat Oncol,2003,13(3):203-213.
  • 5Wernicke AG, Rosenblatt R, Rasca M, et al. Quantitative assessment of radiation-induced fibrosis of the breast with tissue compliance meter, palpation, and radiological imaging: preliminary results [J].Breast J,2009,15(6)'583-592.
  • 6Hayes WC, Herrmann G, Mockros LF, et al. A mathematical analysis for indentation tests of articular cartilage [J]. J Biomech, 1972,5(5):541-551.
  • 7Jurvelin JS, Rasanen T, Kolmonen P, et al. Comparison of optical, needle probe and ultrasonic techniques for the measurement of articular-cartilage thickness [J]. J Biomech, 1995,28(2):231-235.
  • 8Zheng YP, Mak AFT. An ultrasound indentation system for biomechanical properties assessment of soft tissues in-vivo [J]. IEEE Trans Biomed Eng,1996,43(9):912-918.
  • 9Zheng YP, Mak AFT, Lue B. Objective assessment of limb tissue elasticity: development of a manual indentation procedure [J]. J Rehabil Res Dev, 1999,36(2):71-85.
  • 10Zheng YP, Mak AFT. Effective elastic properties for lower limb soft tissues from manual indent/ttion experiment [J]. IEEE Trans P, ehabil Eng, 1999,7(3):257-267.

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部