摘要
广州市城市污水具有有机物浓度低,碳、氮、磷比不合理的特点。采用序批式活性污泥法工艺对广州地区城市污水进行了实验研究。结果表明:在污泥负荷为0.14~0.26kg犤BOD5犦/(kg犤MLSS犦·d)时,出水BOD5为5.12~13.6mg/L,CODCr浓度为10.7~32.2mg/L,NH3-N为2.83~9.23mg/L,TP为0.1~0.45mg/L,证明了采用SBR工艺处理碳氮比较低的城市污水是可行的。
Guangzhou municipal wastewater contains low organic matters and C, N and P ratios are not fitting for conventional biological treatment. A sequencing batch reactor (SBR) process was tested in municipal wastewater treatment. When sludge loading was 0.14~0.26 kg/(kg·d), the indices of effluent from SBR were as follows: BOD5 = 5.12~13.6 mg/L, COD Cr=10.7~32.2mg/L, NH 3-N= 2.83~9.23 mg/L and TP =0.1~0.45 mg/L.The result shows that using SBR to treat municipal wastewater with low content carbon and nitrogen is applicable.
出处
《工业用水与废水》
CAS
2002年第2期18-20,共3页
Industrial Water & Wastewater
基金
建设部2000年度科技计划项目(建科2000285)
广州市建委1998年度科技计划项目(9818)