期刊文献+

预防假体周围溶骨的研究进展

Research progresses of prophylaxis for periprosthetic osteolysis
下载PDF
导出
摘要 在人工关节置换中 ,磨损微粒引起假体周围溶骨已成为当前预防假体无菌性松动的研究重点。本文对近年来为减少磨损微粒的产生、阻止微粒进入假体 骨界面和向远端移动、应用二膦酸盐等的研究作一综述。 In total joint replacement, key point of prophylaxis for aseptic loosening was prophylaxis for periprosthetic osteolysis which was due to particulate wear debris. This paper reviewed the study about reducing the number of wear debris, preventing access of the particles to the bone implant interface and using of bisphosphonates.
出处 《医学研究生学报》 CAS 2002年第2期172-174,共3页 Journal of Medical Postgraduates
关键词 人工关节 溶骨 磨损微粒 预防 Prostheses Osteolysis Wear debris
  • 相关文献

参考文献15

  • 1Maruyama M, Capello WN, D'Antonio JA, et al. Effect of low-friction ion-treated femoral heads on polyethylene wear rates[J]. Clin Orthop, 2000,(370):183-191.
  • 2Sieber HP, Rieker CB, Kottig P. Analysis of 118 second-generation metal-on-metal retrieved hip implants[J]. J Bone Joint Surg Br, 1999, 81(1): 46-50.
  • 3Doorn PF, Mirra JM, Campbell PA, et al. Tissue reaction to metal on metal total hip prostheses[J]. Clin Orthop, 1996,329 (Suppl): S187-205.
  • 4McKellop H, Shen FW, Lu B, et al. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements[J]. J Orthop Res, 1999, 17(2): 157-167.
  • 5McKellop HA, Shen FW, Campbell P, et al. Effect of molecular weight, calcium stearate, and sterilization methods on the wear of ultra high molecular weight polyethylene acetabular cups in a hip joint simulator[J]. J Orthop Res, 1999, 17(3): 329-339.
  • 6Besong AA, Tipper JL, Ingham E, et al. Quantitative comparison of wear debris from UHMWPE that has and has not been sterilised by gamma irradiation[J]. J Bone Joint Surg Br, 1998,80(2): 340-344.
  • 7Fruh HJ, Willmann G. Tribological investigations of the wear couple alumina-CFRP for total hip replacement[J]. Biomaterials,1998,19(13): 1145-1150.
  • 8Emerson RH Jr, Sanders SB, Head WC, et al. Effect of circumferential plasma-spray porous coating on the rate of femoral osteolysis after total hip arthroplasty[J]. J Bone Joint Surg Am, 1999, 81(9): 1291-1298.
  • 9Kraemer WJ, Maistrelli GL, Fornasier V, et al. Migration of polyethylene wear debris in hip arthroplasties: a canine model[J]. J Appl Biomater, 1995,6(4): 225-230.
  • 10Von Knoch M, Engh CA Sr, Sychterz CJ, et al. Migration of polyethylene wear debris in one type of uncemented femoral component with circumferential porous coating: an autopsy study of 5 femurs[J]. J Arthroplasty, 2000,15(1):72-78.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部