摘要 解决国产300MW机组给水低压加热器疏水系统存在的问题,将原设计为疏水逐级自流与疏水泵相结合的连接方式,以疏水逐级自流与外置式疏水冷却器相结合的方式来取代,不仅计算热经济性相当,而且因取消了转动设备疏水泵,提高了系统实际运行的经济性和安全性。 For solving the problems existing in the drain system of low pressure (LP)feed water heaters of indigenous300MW unit,the originally designed connection scheme of cascaded drain flow by itself combined with drain pump was replaced by the connection scheme of cascaded drain flow by itself combined with external drain cooler.In the new connection scheme ,not only the calculated thermal economics was equal ,but also the actual operation economics and safety of the system were improved as a result of the removal of rotary drain pump.
出处 《中国电力》 CSCD 北大核心 2002年第4期73-75,共3页 Electric Power
关键词 疏水系统 技术改进 汽轮发电机组 300MW机组 低压加热器 连接方式 indigenous300MW unit low pressure feed water heater drain system connection scheme improvement