摘要
简要介绍了要因防护矩阵定性分析方法 ,并对核电厂直流电力系统共因故障 (CCFs)进行了定性分析。分析表明 :提出的防护措施可用于排除。
The qualitive analysis method on common cause failures (CCFs)/cause defense matrices is described, and a qualitive analysis on the CCFs probability of DC electric power system in a PWR nuclear power system is given. The analysis results show that the defend measure can be applied to exclude, minish or lighten the probability of CCFs.
出处
《原子能科学技术》
EI
CAS
CSCD
2002年第2期178-182,共5页
Atomic Energy Science and Technology