期刊文献+

软组织应变重建的自适应分段算法 被引量:1

An adaptive selecting method of tracing echo segmentsfor strain profile reconstruction of soft tissue
下载PDF
导出
摘要 生物软组织的弹性系数通常和组织的病理状态有关。弹性成像技术有希望成为软组织病变诊断和力学特性评价的有效手段。基于通常的利用超声回波和时域互相关技术重建组织弹性及应变分布的方法,提出了一种超声回波跟踪波段的自适应筛选算法,以牺牲一定的纵向分辨率为代价来换取重建误差的减小。计算机仿真实验的结果揭示了这种方法的可行性。另外,还提出了一种应变重建前进行数据预处理的方法。 The elasticity of compliant tissue reflects its physiological and pathological characteristics. The technique ofultrasonic elastography based on time delay estimation with cross-correlation is a promising method that may eventuallyallow early detection of many tissue pathologies and assess the biomechanical properties. In this paper, a strain recon-struction method based on adaptive selecting of tracing echo segments is established. It reduces reconstruction errors inthe cost of degradation of axial resolution. The results of computer simulations indicate the feasibility of this method.
作者 罗建文 白净
机构地区 清华大学电机系
出处 《声学学报》 EI CSCD 北大核心 2002年第3期209-212,共4页 Acta Acustica
基金 国家自然科学基金资助项目
  • 相关文献

参考文献2

二级参考文献1

  • 1钟健,硕士学位论文,1993年

共引文献3

同被引文献21

  • 1范宇,白净,李星.人体组织弹性的定征[J].国外医学(生物医学工程分册),1995,18(1):12-20. 被引量:1
  • 2Yemelyanov SY, Skovoroda AR, Lubinski MA, et al. Ultrasound elasticity imaging using Fourier based speckle tracking algorithm. Proc 1992 IEEE Ultrason Symp, 1992; 2:1065.
  • 3Varghese T, Ophir J. Characterization of elastographic noise using the envelope of echo signals. Ultrasound in Med & Biol, 1998; 24(4):543.
  • 4Konofagou EE, Varghese T, Ophir J. Power spectral strain estimators in elastography. Ultrasound in Med and Biol, 1999; 25(7):1115.
  • 5Talhami HE, Wilson LS, Neale ML. Spectral tissue strain: A new technique for imaging tissue strain using intravascular ultrasound. Ultrasound in Med and Biol, 1994; 20(8):759.
  • 6Alam SK, Ophir J, Konofagou EE. An adaptive strain estimator for elastography. IEEE Trans Ultrason Ferroelec Freq Contr, 1998; 45(2):461.
  • 7Bai J, Fan Y, Li X. Tracing echo segment selecting method for strain reconstruction. Ultrasonics, 1999; 37(1):51.
  • 8Bai J, Ding CX, Luo JW. Estimation and reduction of decorrelation effect due to tissue lateral displacement in elastography. IEEE Trans Ultrason Ferroelec Freq Contr, 2002; 49(5):541.
  • 9Kallel F, Prihoda CD, Ophir J. Contrast-transfer efficiency for continuously varying tissue moduli: simulation and phantom validation. Ultrasound in Med & Biol, 2001; 27(8):1115.
  • 10Ophir J, Kallel F, Varghese T, et al. Elastography. Comptes Rendus de l'Academie des Sciences Series IV Physics, 2001; 2(8):1193.

引证文献1

二级引证文献9