摘要
介绍 BIOL AK(百乐克 )工艺应用于处理碱法漂白蔗渣浆污水的实践总结。蔗渣浆污水经过处理后 ,其 p H值、SS、BOD5、CODcr等项目均优于 (GWPB2 1999)《造纸工业水污染物排放标准》的指标。处理 1m3污水的电耗为 0 .5 2kw.h;处理 1m3污水的运行费为 0 .4 6元。
This paper discussed the wastewater treatment of alkaline bleached bagasse pulp with BIOLAK process. After wastewater was treated, its values of pH, SS, BOD5 and CODcr reached the indexes presented in the 'Discharge Standard of Water Pollutants for Paper Industry' (GWPB2-1999). To treat 1m3 wastewater, the electrical consumption was 0 52kw h and the running cost was RMB 0 46 yuan.
出处
《广西轻工业》
2002年第2期18-19,29,共3页
Guangxi Journal of Light Industry