摘要
分析了马钢35000m3/h制氧机组配套的RIK100型空透排气量严重下降的原因,并针对性地采取了一系列措施,彻底解决了问题,达到预期效果。
An analysis was made on serious reduction causes of air discharging capacity of RIK100air turbine matched with 35000m 3 /h oxygen making unit of Maanshan Iro n &Steel Co.Ltd.A series of measures were adopted,which solved the problems thoroughly and ob-tained predicted effects.[
出处
《冶金动力》
2002年第1期17-18,共2页
Metallurgical Power