摘要
本文介绍了18根冷弯薄壁槽钢柱的相关屈曲试验观测结果,并简要地介绍了作者的理论分析方法。在试验过程中采用了先进的光栅技术,获得了加载过程中柱子壁板屈曲后的波形变化规律。基于试验与现行薄壁型钢规范的比较,提出了现行规范的修改建议式。
An experimental study on the local and overall interaction buckling strength of thin-walled channel section columns is presented in this paper.A total of eighteen columns with large width-thickness ratios were tested to failure. The advanced moire fringe method had been used in the process of experiment and some important conclusions on waveshape variation were obtained from a series of fringe patterns of buckled plates forming the column.A new analytical approach was also outlined and the details of theoretical formulation of equation were given in Ref,[1].The experimental results have been compared with author's theoretical solutions and P.R.C. current specification and a modified Perry's formula for designing centrally loaded channel section columns is proposed to predict the interaction buckling strength.
出处
《土木工程学报》
EI
CSCD
北大核心
1991年第1期23-31,共9页
China Civil Engineering Journal
基金
国家自然科学基金