摘要
本文通过对株冶4台主供动力变压器经济负载区的分析推导,阐述了在利用现有设备基础上,调整其容量与负荷的适配状况,提高变压器运行效率的可行性和途径,分析了负荷调整后的效果与效益。
On the basis of analysing of economic load section of 4 main power supply transformers, this paper explained that based on utillization existing equipments, regulating the suitable condition of content and load, raised the feasibility and the way of efficiency of transformer. This paper also analysed the effects and benefits after regulation.
出处
《有色冶金节能》
2002年第1期23-26,35,共5页
Energy Saving of Nonferrous Metallurgy
关键词
变压器
效率
负荷率
损耗
transformer
efficiency
load rate
loss