低温液体输送系统间歇泉现象机理分析与消除措施 被引量:16

Physical Mechanism and Elimination of the Geysering Effect in Cryogenic Liquid Transfer System
下载PDF
导出
摘要 在低温液体输送系统的垂直管路中有可能发生间歇泉现象 ,对管路系统和液体储存都会产生不利影响。文中从气泡动力学、间歇泉循环过程、管路结构等方面对低温液体输送系统中出现的间歇泉现象进行了机理分析 ,介绍了几种消除间歇泉现象的措施 。 In this paper, physical mechanism of geysering in cryogenic liquid transfer system is analyzed. The discussion will be divided into three main subdivisions:bubble dynamics, geysering cycle and pipe structure, several approaches are listed as possible ways to reduce and eliminate geysering. All of this fundamental theory will be used in later studies of geysering phenomena.
出处 《低温与超导》 CAS CSCD 北大核心 2002年第2期1-6,共6页 Cryogenics and Superconductivity
  • 相关文献

参考文献5

  • 1[1]Paniagua J, Rohatgi U S, Prasad V, Modeling of thermal hydraulic instabilities in single heated channel loop during startup transients, Nuclear Engineering and Design, 1999, 193 (1- 2): 207
  • 2[2]Morioka Mikio, Obama, Toshio, Simulation of the geysering phenomenon in LNG pipes, Advances in Cryogenic Engineering, 1986, 31:1111-1119
  • 3[3]Howard F S, Geysering inhibitor for vertical cryogenic transfer piping, Advance in cryogenic engineering, 1973, 18: 162-169
  • 4[4]Murphy D W, An experimental investigation of geysering in vertical tubes, Advance in cryogenic engineering, 1965, 10:353-359
  • 5[5]Morgan S K, Brady H F, Elimination of the geysering effect in missiles, Advance in cryogenic engineering, 1962, 7 : 206-213