摘要
采用流动注射技术研究了酸性条件下 ,延胡索乙素与高锰酸钾和硫代硫酸钠的化学发光行为 ,对影响化学发光强度的诸因素进行了实验和探讨 ,建立了流动注射化学发光法测定延胡索乙素的新方法 .方法的检出限为 3× 10 - 8g/mL ,线性范围为 1.0× 10 - 7~ 8.0× 10 - 5g/mL ,对 4 .0×10 - 6g/mL延胡索乙素进行 11次平行测定 ,相对标准偏差为 1.6 % .方法用于药剂中延胡索乙素的测定 。
An analytical method consisting of flow-injection samping and chemiluminescence detection for determination of tetrahhydropalmatine is described.It is based on the chemiluminescence reaction of KMnO 4-Na 2S 2O 3-tetrahydropalmatine system.The chemiluminescence intensity was correlated linearly with concentration of tetrahydropalmatine in the range of 0.1~80.0mg/L.The determination limit is 0.03mg/L.The relative standard deviation is 1.6% for 11 measurements of 4.0 mg/L tetrahydropalmatine standard solution.The method has been applied to the determination of tetrahydropalmatine in pharmaceutical preparations and the results are in good agreement with those by standard method.
出处
《山东大学学报(理学版)》
CAS
CSCD
北大核心
2002年第1期78-79,83,共3页
Journal of Shandong University(Natural Science)