摘要 目的:探讨自制的大动物实验性原位肝移植术体外静脉转流泵的可行性。方法:施行猪的原位全肝移植术15例,术中使用自制的静脉转流泵,行体外静脉转流。结果:在排除了固手术操作失误等原因引起的失败以外,术后4例在没有使用免疫抑制剂的前提下,获得了1周以上的存活(最长达 67天)。术后谷丙转氨酶(Alaninetransaninase,ALT)的峰值出现在术后第1天,以后渐降。结论:自行研制的静脉转流泵是一个实用的大动物肝移植工具,具有简便、轻巧,价格低廉的优点。 Objective: To disign a new extracorporeal venous bypass pump for experimental orthatopic liver transplantation ( OLT) in big animals. Methods: OLT was performed in 15 pig models,and a modified extracorporeal venous bypass pump was applied during the operations. Results: After the exclusion of failure caused by technical fault,4 animals survived over 1 week after the operations (67 days for the longest) without immunosuppressive therapy. The peek level of alanine transaminase ( ALT) appeared on day 1 after the operations, and then decreased gradually. Conclusion: The modified extracorporeal venous bypass pump is a useful instrument for OLT in big animals, which is low-cost, portable and easily operative.
出处 《广州医学院学报》 2002年第1期50-52,共3页 Academic Journal of Guangzhou Medical College
关键词 肝移植 静脉转流泵 临床应用 liver transplantation extracorporeal venous bypass pump
  • 相关文献

参考文献5

  • 1许学兵,佘守章,古维立,庄思敏,董源洪.猪原位肝移植围手术期肝功能的变化[J].中华麻醉学杂志,2001,21(7):433-434. 被引量:1
  • 2Starzl TE,Koep LJ,Halgrimson GG,et al.Fifteen years of clinical liver transplantation[J].Gastroenterology,1979,77:375-388.
  • 3Millis JM,Melinek J,Csete M,et al. Randomized controlled trail to evaluatee flush and reperfusion techeniques in liver transplantation[J]. Transplantation,1997,63:397-403.
  • 4Klein M,Geoghegan J,Wangermann R,et al. Preconditioning of donor livers with prostaglandin I2 before retrivel decreases hepatocellular ischemia-reperfusion injury[J]. Transplantation,1999,67:1128-1132.
  • 5林建华,李朝龙,周占春,林智琪.猪原位肝移植的体位静脉转流[J].中华器官移植杂志,2000,21(2):79-80. 被引量:6

二级参考文献3

共引文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部