摘要
我们用原子吸收分光光度法和X光谱法系统地研究了干法灰化植物标准样GSV-1和GSV-2的灰化温度和灰化时间与元素损失的关系,研究了植物样品的八种前处理方法。实验得出的结论,完全适合于其它植物样品。
:
Using atomic absorption spectrophotometry and X-ray fluorescence spe-
ctrometry, we studied systematically the relations of ashing temperature,ashing
time and loss of element collcentration for dry ashed vegetation standard sa-
mples GSV-1 and GSV-2, and investigated eight processing methods for these
vegetation samples. The conclusions drawn from the experiments are comple-
tely suitable for other vegetation samples.
出处
《物探与化探》
CAS
CSCD
1991年第2期99-105,共7页
Geophysical and Geochemical Exploration