介绍一种转轮除湿与冷却除湿相结合的复合式除湿工艺空调系统。分析比较氯化钙、乙二醇冷冻水载冷剂在同一温度之间及同一载冷剂在不同温度下的换热系数差异,分析该工艺空调系统不能正常运行的原因,并提出改进措施。
Analyses a hybrid dehumidification process air conditioning system of desiccant wheel combined with cooling dehumidification.Compares the difference of the convective coefficient of heat transfer between the different secondary refigerant in the same and different temperature. Discusses the causes for poor operation of the process air conditioning system and puts forward some corresponding improving methods.
出处
《洁净与空调技术》
2002年第1期13-16,26,共5页
Contamination Control & Air-Conditioning Technology
关键词
转轮
冷却除湿
复合式除湿
空调系统
Desiccant wheel dehumidification Cooling dehumidification Secondary refrigerants Process air Reactivation air