摘要
针对数字控制技术的特点 ,分析了在选择性谐波消除法的理论计算结果与实际开关角数字控制结果出现偏差时 ,对逆变器输出电压谐波含量的影响 .并研究了开关角数量对逆变器性能的影响 ,结果表明 :开关角控制误差对逆变器输出谐波有一定影响 ,但可以在计算时修正 ;而开关角数量的增加有利于减小电流脉动 ,提高输出电压质量 。
This paper analyzes the influence of the error between the calculated results by selective harmonic elimination and the digit_controlled results on the output of inverter. It also studies the effect of the number of the switching angles on the inverter performance. The results show that the control errors affect the inverter output_vltage but can be reduced in the calculation period. The study has proved that the current ripple can be reduced and the output voltage quality can be enhanced by increasing the numbers of switching angles, but in the meantime, the switching frequency is heightened.
出处
《华南理工大学学报(自然科学版)》
EI
CAS
CSCD
北大核心
2002年第4期33-36,共4页
Journal of South China University of Technology(Natural Science Edition)
基金
国家自然科学基金资助项目 (5 0 0 0 70 0 1)
关键词
逆变器
预置开关角
误差
输出谐波
开关器件
inverter
selective harmonic elimination technique
single chip control