期刊文献+

密封消解法测定高氯离子含盐废水COD_(Cr)的探讨 被引量:15

The Discussion on the Measurement of COD_(Cr) of Salty Waste Water with High Content of Chlorine Ion by the Method of Sealed Clearing Up
下载PDF
导出
摘要 针对国标重铬酸钾法测定高氯离子含盐废水CODCr时的不足,提出用密封消解法来测定高盐废水CODCr的观点,通过丁酮氧化率、氯离子干扰、混配水样和实际水样测定结果的比较,对国标法和密封消解法进行了验证。试验结果表明:在测定高氯离子含盐废水CODCr值时,密封消解法优于重铬酸钾法,能够真实准确地反映废水的CODCr。 In view of the inefficiency of measurement of CODCr of salty waste water with high content of chlorine ion by the method of heavy potassium chromate, the method of sealed clearing up to measure CODCr of salty waste water with high content of chlorine ion is introduced. Through the comparison between two methods in terms of oxidation rate of butanone, interference of chlorine ion, mixed water sample and actual water sample, the two methods are introduced in detail. The result of experiment shows that while measuring CODCr of salty waste water with high content of chlorine ion, the method of sealed clearing up is better than that of heavy potassium chromate, in terms of accurate measurement of CODCr of waste water.
出处 《油气田环境保护》 CAS 2002年第1期38-40,共3页 Environmental Protection of Oil & Gas Fields
基金 中国石化集团公司重点科研课题<胜利油田采油废水达标处理>的子课题之一
关键词 高盐废水 废水监测 CODCR 重铬酸钾法 密封消解法 waste water with high content of salt, CODCr, method of heavy potassium chromate, method of sealed clearing up
  • 相关文献

参考文献1

  • 1范燕英.高氯化物废水中COD测定方法的研究[J].化工环保,1987,7(3):152-159.

共引文献3

同被引文献98

引证文献15

二级引证文献93