摘要
研究了大气中痕量二硫化碳在 SQ-2 0 6(以 1 0 %的 SE-3 0为固定液 ,配火焰光度检测器 )上的测定方法及二硫化碳的富集和解吸条件的选择。以碳分子筛为吸附剂 ,最佳收集速度为 2 0 ml/min,解吸液体积 1 5 ml,解吸时间 3 5 min。用外标法定量 ,测定的回收率为 99.2 % ,最低检出浓度 2 .0 4× 1 0 - 8g/
In the paper, the method for determination of trace amount of carbon disulfid in air was studied by model SQ 206 gas chromatograph with 10% SE 30 and flame photometric detector The conditions of concentrator and desorption of carbon disulfid were studied With the absorbent of carbon molecular sieve The optimun desorption velocity, desorption volume and desorption time are 20ml/min, 15 ml and 35 min The recovery of sample was 99 2% The detection limit and recovery are 2 04×10 -8 g/L, 99 2%
出处
《中国环境监测》
CAS
CSCD
北大核心
2002年第1期30-32,共3页
Environmental Monitoring in China
关键词
二硫化碳
气相色谱
分析
富集
carbon disulfide
gas chromatography
analysis
concentrator