对某燃煤电厂地下卸煤间的测试结果表明 :当燃煤全水分为 11%时 ,即使不采取水雾除尘措施 ,卸煤间内粉尘浓度也可达到国家职业安全卫生标准。结合该电厂实测数据 。
Measurements in underground coal unload cabinet of a coal fired power plant indicate that the dust concentration in the cabinet can meet national labour safty and health standards even without water spray precipitator if the coal contains 11% or more water.According to the measurement data,the influence of water content in coal on combustion efficiency of boiler is estimated using a computer program.
出处
《电力环境保护》
2002年第1期13-14,共2页
Electric Power Environmental Protection
关键词
燃煤电厂
喷水雾除尘
含尘浓度
燃烧效率
coal fired power plant
water spray precipitator
dust concentration
combustion efficiency