电容式电压互感器高频响应特性差,满足不了对电压行波测量的要求。该文利用测量电容式电压互感器(CVT)的入地电流行波来检测线路电压行波,设计了行波传感器,提出了硬件行波波头检测方法,并应用于基于整个电网的行波故障定位。仿真分析及装置实验测试表明:该方法实现简单、安装方便、鲁棒性强、定位精度高。该技术已申请国家发明专利。
The voltage traveling-wave in transmission line is difficult to be accurately detected in the secondary of capacitive voltage transformer (CVT) which has bad character to transform high frequency signals. A new sensor to detect the voltage traveling-wave is designed in this paper. It can measure the current traveling-wave from CVT to ground. The incipient times of traveling-wave appearing in every station are measured and a new fault location system for the whole grid is implemented. Simulations and prototype testing show that this fault location method has high precision and can be implemented easily and cheaply.
出处
《中国电机工程学报》
EI
CSCD
北大核心
2002年第6期42-46,共5页
Proceedings of the CSEE
关键词
行波传感器
输电线路
故障定位
高频响应特性
fault location
traveling-wave sensor