介绍了韶关发电厂DG10 2 5 / 18 2 Ⅱ 10型“W”火焰锅炉燃烧技术特点及“W”型火焰锅炉冷态试验模化技术 ,根据其火焰为“W”型和燃烧对称的燃烧特点 ,对该炉的冷态试验内容与方法进行了初步的探讨及分析 ,认为“W”
This paper describes the combustion technical features of W firing boiler DG1025/18 2 Ⅱ10 in Shaoguan Power Plant and the cold test modular technology of W firing boilers. The cold test content and manner of the boiler are approached based on its features of W shape flame and symmetrical combustion. It is indicated that the cold test of the boiler should consist of static check and furnace air distribution.
出处
《广东电力》
2002年第2期23-26,共4页
Guangdong Electric Power