摘要
用逻辑流图法对天脊集团 110kV主线接线进行了可靠性计算 ,得出各 6kV负荷点的可靠度及故障率 。
Based on the logical flow diagram,this paper calculates the reliability of the 110kV main connections in Tianji Group and gets both the reliability and malfunction rate at each 6kV load point, which will provide a reference for the operating and maintaining of this power supply system.
出处
《大氮肥》
CAS
2002年第3期213-215,共3页
Large Scale Nitrogenous Fertilizer Industry