用热电离质谱仪检测负离子 ,因技术上的原因 ,一直是国际质谱界关注的热点问题之一。近几年来 ,在此领域的探索取得突破 ,发展迅速。新型号的质谱上已大量使用这一技术。国内也填补了这一领域的空白 ,并将这一技术成功运用于老质谱仪的升级改造。本文重点阐述了作者本人在探索过程中遇到的疑难问题及解决问题的有效方法。
Detecting negative ions by thermal ionization mass spectrometer (TIMS) was one of the most important hot spots in the mass spectrometry field.Major breakthrough in this field has been made resently.The application of this new technique has become popular in the world.In this paper,some problems and difficulties in the practical use of TIMS and method to solve them were discussed and proposed.
出处
《矿物岩石》
CAS
CSCD
北大核心
2002年第2期43-46,共4页
Mineralogy and Petrology
基金
国家科技部大型精密仪器改造项目基金资助
关键词
热电离质谱计
负离子检测
负高压
分压系统
同位素
thermal ionization mass spectrometer
negative ions detect
negative high voltage
HV divider