期刊文献+

低能电弧放电模型比较分析 被引量:12

Comparisons of Mathematical Models of Low Energy Arc Discharge
下载PDF
导出
摘要 比较了低能电弧放电电流线性衰减模型和动态伏安特性模型 .指出两者在反映最小建弧电压、放电瞬间的电流下降率和放电时间这 3个参数上是一致的 .但是对于反映放电能量的两个组成部分之间的比值这一参数上 ,前者的结论是该比值只与电源电压有关 ,而后者的结论是该比值与电源电压和电路电感都有关 .分析发现电流线性衰减模型是动态伏安特性模型的特例 。 The current linear attenuation model and dynamic V A characteristics model were compared. The result shows that both of the models are coincided with each other in the following three parameters: minimum arcing voltage,current drop rate at the moment of discharge and discharge time. But for the ratio of arc discharge energy components, it is related to the source voltage based on the former model, and to both the source voltage and the circuit inductance based on the latter model. It can be concluded that the former model is a special case of the latter one, which can solve the problem mentioned above.
出处 《中国矿业大学学报》 EI CAS CSCD 北大核心 2002年第2期201-203,共3页 Journal of China University of Mining & Technology
基金 国家自然科学基金资助项目 ( 5 0 0 770 2 2 )
关键词 低能电弧 本质安全 放电能量 本质安全电路 数学模型 动态伏安特性模型 low energy electrical arc intrinsically safe discharge energy
  • 相关文献

参考文献4

  • 1刘鸿浩,李全.电感性本质安全电路电弧放电的理论分析与实验研究[J].煤炭学报,1990,15(2):15-22. 被引量:6
  • 2章良海.安全火花电路[M].北京:煤炭工业出版社,1983.15-32.
  • 3孟庆海.本质安全电路电弧放电数学模型及非爆炸方法评价电路本质安全性能[M].徐州:中国矿业大学信息与电气工程学院,1999..
  • 4张丙军.安全火花电路[M].北京:煤炭工业出版社,1981.112-113.

二级参考文献2

  • 1王其平,电器中的电弧理论,1982年
  • 2张丙军,安全火花电路,1981年