摘要
对水冷壁管同一根、同一区域发生的两起爆管事故进行失效分析 ,研究爆管机理 ,找出了爆管原因 。
Failure analysis is made upon two explosive cracking accidents on the same area of the same pipe of a water-cooling system,and the failure mechanism is investigated.At the same time, the preventive measures are searched for.
出处
《新疆石油学院学报》
2002年第2期72-76,共5页