摘要
分析了现有激光器维修性差的现状 ,给出了一种免调试激光器 ,并对该激光器进行了维修性验证试验 ,结果平均修复时间由原来的 8.1 2h减少到 0 .81 2
The present status of laser maintainability is not ideal,so an adjust free laser is put forward and maintainability test experiment has been done on the laser.It shows that the mean time to repair reduces form 8.12h to 0.8125h .
出处
《激光技术》
CAS
CSCD
北大核心
2002年第3期229-230,共2页
Laser Technology
关键词
维修性
激光器维修性
免调试激光器
maintainability
laser maintainability
adjust free laser