摘要
本文介绍了预热段设置有交错扼流装置的650开坯加热炉,内容包括交错扼流装置的设置、结构特点,以及它的作用与效果。两年多来的运行表明,采用下排烟的这座炉子,装料门处的炉压一直处于零压或微负压,它的炉尾排烟温度与同类650加热炉相比,降低了200~250℃。
This paper presents an introduction to 650 blooming reheating furnace which has crisscross choker at the preheating section. It includes the installation of the crisscross choker, its structure features and its effects. Past two years'operation shows that, in the furnace which uses bottom fume offtake, the furnace pressure at the charge door remains zero or slightly below zero and that compared with other 650 blooming reheating furnace the fume offtake temperature at furnace rear is reduced by 200^-250℃.
出处
《冶金能源》
1991年第6期36-39,共4页
Energy For Metallurgical Industry