摘要
分析了烧结机机尾收尘系统存在的问题 ,比较了拟采用的改造方案 ,改造后系统粉尘排放浓度和 6 0 m烟囱 SO2 浓度超标。
The paper describes the analyses of the current problem of the dust collection system at the sinter machine discharge and comparison of modification alternatives to be adopted. It presents the results of the modification that both dust discharge density of the dust collection system and emission concentration of SO 2 of 60 m stack are in compliance with that specified in the standards, thus eliminating effectively the low altitude pollution from the sinter machine discharge.
出处
《有色冶炼》
2002年第2期40-42,共3页
Non-Ferrous Smelting
关键词
烧结机
收尘系统
SO2烟气
sinter machine
dust collection system
SO 2 gas