摘要
该文通过对湘潭电厂CC5 0 8.83/3.73/1.4 7型汽轮机第十三级叶片断裂事故分析 ,找出叶片断裂原因并提出限负荷方案。图 4表
By analyzing the 13 th stage's blade failure of Xiangtan Power Plant's CC50 8.83/3.73/1.47 type steam turbine, the paper explains the factors that caused the failure and suggest load cutting as solution. Figs 4 and table 5.
出处
《发电设备》
2002年第4期1-4,39,共5页
Power Equipment
关键词
湘潭电厂
汽轮机
叶片断裂
强度校核
故障处理
steam turbine
blade rupture
strength recalculation
failure analysis