摘要 目的 探讨不同剂量的氟碳声学造影剂在正常肾脏显影中的增强效果与变化规律。方法  10只健康新西兰白兔经耳缘静脉注射氟碳声学造影剂 ,剂量水平分别为 0 0 1、0 0 2、0 0 4ml/kg ,用基波显像 (FI)及二次谐波显像 (SHI)观察肾脏造影增强效果。结果  3种剂量水平均可使肾皮质明显增强 ,尤其以二次谐波显像强烈。除了SHI组 0 0 4水平有显著差异外 ,剂量 效应关系不敏感。FI造影中产生明显的声影伪像 ,而SHI在低剂量水平 (0 0 1、0 0 2ml/kg)避免了声影出现。结论 低剂量水平的造影剂即可实现显著的肾脏造影效果 。 Objective To assess the relationship of doses with enhancement effects of contrast agent in ultrasonography for normal kidney. Methods Perfluorocarbon ultrasound agent were administered to 10 normal rabbits through ear veins at 0.01, 0.02, 0.04 ml/kg, respectively. Second harmonic imaging (SHI) and fundamental imaging (FI) were performed on right kidney. Results The gray scales of normal kidney parenchyma were significantly enhanced with the 3 different doses, especially in second harmonic images. The dose enhanced effect relationship varied insensitively except in 0.04 ml/kg of SHI. The acoustic shadows of contrast kidney were visualized in all doses with FI, and were only observed in 0.04 ml/kg in SHI. Conclusion Perfluorocarbon ultrasound agent remarkably improves normal kidney even at low dose, and SHI avoids the influence of acoustic shadow.
出处 《第三军医大学学报》 CAS CSCD 北大核心 2002年第6期743-744,共2页 Journal of Third Military Medical University
关键词 肾脏 增强显影 造影剂 剂量 动物实验 ultrasound contrast agent dose normal kidneys rabbits
  • 相关文献

参考文献1

二级参考文献2

共引文献2

同被引文献44

  • 1李卓,龚渭冰,刘红梅,崔忠林,黄红波,孙煦勇.经静脉声学造影法与彩色多谱勒法对移植肾急性排异反应诊断的对比研究[J].第一军医大学学报,2003,23(5):439-441. 被引量:9
  • 2马艳,龚渭冰,侯连兵,马俊杰.移植肾急性排斥血流灌注与生化指标变化关系的实验研究[J].中国超声医学杂志,2005,21(7):490-493. 被引量:10
  • 3龚渭冰,马艳,侯连兵,贺京军.超谐波声学造影评价移植肾急性排异血流灌注的实验研究[J].中华超声影像学杂志,2005,14(8):625-628. 被引量:9
  • 4Tiefenthaler M,Riedl-Huter C. Value of sonography in kidney transplantation. Acta Med Austriaca,2001,28:74-77.
  • 5Claudon M,Lefevre F,Hestin D,et al. Power Doppler imaging: evaluation of vascular complications after renal transplantation. Am J Roentgenol,1999,173:41-46.
  • 6Bouakaz A,Frigstad S,Ten Cate FJ,et al. Improved contrast to tissue ratio at higher harmonics. Ultrasonics,2002,40:575-578.
  • 7Claudon M,Barnewolt CE,Taylor GA,et al. Renal blood flow in pigs: changes depicted with contrast-enhanced harmonic US imaging during acute urinary obstruction. Radiology,1999,212:725-731.
  • 8Georage AT,Carol EB,Brent H,et al. Renal cortical ischemia in rabbits revealed by contrast-enhanced power Doppler sonography. Am J Roentgenol,1998,170:417-422.
  • 9Lefevre F,Correas JM,Briancon S,et al. Contrast-enhanced sonography of the renal transplant using triggered pulse-inversion imaging: preliminary results. Ultrasound Med Biol,2002,28:303-314.
  • 10Gaschen L,Schuurman HJ. Ultrasound score is more predictive than serum creatinine in assessment of cellular rejection in cynomolgus monkey renal allografts. Invest Radiol,2002,37:376-380.

引证文献5

二级引证文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部