摘要
采用微电解-接触氧化-过滤-吸附工艺处理甲壳素生产废水,结果表明:铁炭微电解对CODCr的去除率达30%,pH由0.7提高到5.5;生化处理的CODCr去除率达80%以上。
Microelectrolysis contact oxidation filtration adsorption process was used to treat chitin production wastewater.The results show that iron carbon microelectrode can reduce 30%of CODCr,pH value can be raised to 5.5 from 0.7,the removal efficiency of CODCr by biological treatment exceeds 80%.
出处
《工业用水与废水》
CAS
2002年第3期24-26,共3页
Industrial Water & Wastewater
关键词
甲壳素
生产废水
废水处理
微电解
接触氧化
chitin production wastewater
wastewater treatment
microelectrolysis
contact oxidation