介绍了山西阳光发电有限责任公司 1号炉采用全挥发处理存在的问题及进行平衡磷酸盐处理的试验情况。试验结果表明亚临界参数锅炉内水处理方式采用平衡磷酸盐处理是切实可行的 ,并对
It introduces the existing problems with complete volatilized process and the experimental results with balanced phosphate treatment in No.1 boiler of Yangguang power Ltd.Co.,And summarized the advantages of the balanced phosphates process in 4 boilers.The experimental results declared that it is actually feasible with balanced phosphates treatment way in subcritical boiler.