摘要
讨论了并 串联单孔单响微差爆破网络的约束条件 ,探讨了雷管起爆误差对这种爆破网络的影响 ,指出采用国产导爆管雷管的起爆误差波动范围太大。欲达到单孔单响目的 ,每排最多不能超过 3孔。
The restriction conditions of parallel-series single hole-single shot millisecond blasting network are discussed. The effect of electric detonator initiation's error on the blasting network is also discussed. Domestic detonators have a wide error range of initiation. As a result, to achieve the single hole-single shot initiation, it is necessary for each row to have 3 holes at most.
出处
《矿冶工程》
CAS
CSCD
北大核心
2002年第2期34-36,共3页
Mining and Metallurgical Engineering
关键词
单孔单响
爆破工程
导爆管雷管
爆破网络
blasting engineering
non-electric detonator
blasting network