摘要
介绍了南昌钢铁厂新安装的一台轴流压缩机机组振动测试的情况 ,深入分析了机组故障原因 ,制定了故障治理方案 。
The vibration test results and fault diagnosis process are presented in detail. The looseness of bearing pad and rotor to stator rub are the two main causes of the abnormal vibration. The defects of the compressor were solved based on the fault diagnosis project. The vibration turns to good after the repair.
出处
《流体机械》
CSCD
2002年第6期30-33,共4页
Fluid Machinery
基金
国家重点基金研究发展规划项目 (G199980 2 0 30 0 )
国家自然科学基金项目 ( 50 0 0 50 0 4 )