期刊文献+

镍钛机动器械预备弯曲根管的研究进展 被引量:9

Research Advance in Preparing Curved Root Canals with Nickel-Titanium Rotary Instruments
下载PDF
导出
摘要 弯曲根管的预备是根管治疗中的难点,镍钛合金制成的根管机动预备器械具有良好的成形能力和抗腐蚀性能,在弯曲根管预备中,亦能取得满意的成形和清理效果,临床应用前景良好。但是,镍钛器械的折断仍为亟待解决的问题。
作者 韦曦 凌均棨
出处 《上海口腔医学》 CAS CSCD 2002年第2期158-160,共3页 Shanghai Journal of Stomatology
  • 相关文献

参考文献25

  • 1[1]Walia H,Brantley WA,Gerstein H. An initial investigation of the bending and torsional properties of nitinol root canal files [J]. J Endod, 1988, 14(7):346-351.
  • 2[2]Samyn JA, Nicholls JI, Steiner JC. Comparison of stainless steel and nickel-titanium instruments in molar root canal preparation [J]. J Endod, 1996, 22(3):177-181.
  • 3[3]Glosson CR, Hailer RH, Dove SB, et al. A comparison of root canal preparation using NiTi hand, NiTi engine-driven, and KFlex endodontic instruments [J]. J Endod, 1995, 21(3):146-151.
  • 4[4]Manufacture's instruction, Maillefer ProFile IFY/F 19 02 21.E /01/98/5000/[H],Switzerland.
  • 5[5]Kavanagh D, Lumley PJ. An in vitro evaluation of canal preparation using ProFile.04 and .06 taper instruments [J]. Endod Dent Traumatol, 1998, 14:16-20.
  • 6[6]Manufacture' s instruction[H].Lightspeed Technology Inc. 11/98/US.
  • 7[7]Thompson SA, Dummer PMH. Shaping ability of Lightspeed rotary nickel-titanium instruments in simulated root canals. Part 1-2 [J]. Int Endo J, 1997, 30:262-278.
  • 8[8]Manufacture' s instruction[H].Quantec by Tycom. US.
  • 9[9]Manufacture' s instruction, Maillefer GT Rotary Files IFY/F19[H]. 02 23.E/01/99/10 000/Switzerland
  • 10[10]Thompson SA, Dummer PMH. Shaping ability of ProFile.04 taper series 29 rotary nickel-titanium instruments in simulated root canals. Part l&2 [J]. Int Endod J, 1997, 30:1-15.

同被引文献39

  • 1高燕,凌均棨.上颌磨牙近中颊根第二根管口的解剖定位[J].口腔医学,2004,24(3):135-136. 被引量:40
  • 2韦曦,黄湘雅,曾志平,任邦鹏.手用ProTaper镍钛器械根管清理效果的扫描电镜研究[J].牙体牙髓牙周病学杂志,2004,14(12):677-680. 被引量:25
  • 3倪龙兴,王胜朝.现代根管治疗术:根管预备[J].实用口腔医学杂志,2005,21(4):566-568. 被引量:16
  • 4肖卫,邬继东.根管内器械折断的原因和处理[J].口腔材料器械杂志,1996,5(2):92-92. 被引量:1
  • 5Roland D, Andelin WE, Browning DF, et al. The effect of preflaring on the rates of separation for 0.04 taper nickel titanium rotary instruments. J Endod, 2002, 28(7) : 543 -545.
  • 6Blum JY, Machtou P, Micallef JP. Location of contact areas on rotary Profile instruments in relationship to the forces developed during mechanical preparation on extracted teeth, lnt Ended J, 1999,32 : I08.
  • 7Blum JY, Cohen A, Machtou P, et al. Analysis of forces developed during mechanical preparation of extracted teeth using Profile NiTi rotary instruments. Int Ended J, 1999, 32:24 -31.
  • 8Elio B, Alfonso KN, Mario L, et al. Influence of manual preilaring and torque on the failure rate of ProTaper rotary instruments. J Endod, 2004, 30 : 288 - 330.
  • 9Arens FC, Hoen MM, Steiman HR, et al. Evaluation of single - use rotary nickel - titanium instruments. J Endod, 2003, 29 (10) : 664 -666.
  • 10Peter P, Ian G, Harold H. Messer. Factors influencing defects of rotary nickel - titanium endodontic instruments after clinical use. J Endod, 2004, 30 : 722 - 725.