对 4种混凝剂用于电厂废水处理进行了研究 .首先确定pH值 ,大区间搜索较好加药量范围 ;进一步缩小加药量区间 ,寻找最好加药量 ;然后改变pH条件 ,寻找最佳加药量及最佳pH条件等最佳工艺参数 .
Four kinds of coagulants are used to treat waste water from power plant. Firstly,pH value is fixed. Experiments are done on a wide range of coagulant dosages. Then the range is narrowed to find out the best dosages .Secondly, pH value is changed to search for the best dosage and pH value of every coagulant .The result of experiment shows the treated waste water can be used for power plant recycling.