摘要
通过对三种燃料在0.3MW循环流化床上燃烧的热态试验,研究并分析了一次风量对循环流化床内沿床高的中心温度分布的影响,所得结论对流化床的试验研究和实际运行有一定参考意义。
In the paper,we study the center temperature distribution characteristic along height of CFB on a experimental rig with0.3MW heat output.The primary air influencing center temperature distribution along height of CFB and solid circulating flux s recognized and analyzed with three kinds of coal.The conclusions acquired have significant meaning for operating CFB boiler in practice and experimental research.
出处
《工业锅炉》
2002年第2期4-7,共4页
Industrial Boilers
关键词
循环流化床
燃烧
一次风
Circulating fluidized bed
Combustion
Primary air