摘要
对绥中发电有限责任公司 800 MW机组锅炉燃烧器烧损原因进行全面详尽的分析,通过分析和试验提出了具体的解决办法并加以实施,彻底解决了绥中发电有限责任公司 800 MW机组在启动燃油阶段发生的燃烧器烧损问题。
The comprehensive and detailed analyses had been carried out for the burn-out causes of burners on 8O1 MW generating boiler in Suizhong Generation Liability Company Limited. Through analyses and tests the concreate solutions were put forward and executed, then burner burn-out problems happened in the starting oil-firing stage of 800 MW generating set of Suizhong had been thoroughly solved.
出处
《东北电力技术》
2001年第6期11-13,共3页
Northeast Electric Power Technology