摘要 在用平行光管视差仪或视度筒检测光学仪器的视差时 ,检测结果受人的主观影响太大。为此 ,提出了应用CCD进行视差智能化检测的方法 ,并推导出了用该方法检测的理论依据。通过与视度筒检测的结果相比较 ,发现二者基本一致。该方法不但具有快速、定量化检测的特点 ,而且能直观的给出视差量的大小 。 The test result is influenced by the human subjectivity when parallax is measure d with collimation converter parallaxometer or diopter cylinder. So the in telligent method which uses CCD camera is presented and its theoretic basis is d educed. The experimental relults are basically consistent with those obtained fr om diopter cylinder. The new method not only have the feature of rapidity and q uantification but also give the result intuitively. The aim of automatic measuri ng is reached.
出处 《光学技术》 CAS CSCD 2002年第4期365-366,共2页 Optical Technique
关键词 光学仪器 视差 自动检测 CCD摄像机 parallax automatic measurement CCD camera
  • 相关文献

参考文献3

  • 1程守澄.光学仪器检疫[M].北京:兵器工业出版社,1992..
  • 2王永中.智能光电系统[M].北京:科学出版社,1998..
  • 3C H 塞甘.电荷转移器件[M].北京:科学出版社,1979..