摘要 本文研究了钪-5-Br-PADAP-Triton X-100显色体系的光度特性,并确定了钪测定的最佳条件.用单双波长法测定时,钪浓度均在0—11μg/10ml范围内遵循比尔定律,其表现摩尔吸光系数分别为5.9×10~4和7.5×10~4.Triton X-100的加入未能增敏,但能增溶,并显著提高了体系的选择性.从而建立了在水相中测定钪的新方法.用于镁基合成试样中钪的测定,结果满意. The photometric properties of chromogenic system of scandium-5-Br-PADAP-triton X-100 were studied. The optimum condition for determining scandium havebeen found. The system obeys Beer's law in the range of 0-11 μg/10ml by both single-and dualwavelength methods and their apparent molar absorptivities are 5.9×104 and 7.5×104 1·mol-1·cm-1 respectively. Adding Triton X-100 has no sensitization, but has solubilization and obviously increases selectivity of the system. A new method for determining scandium in water phase is proposed and is applied to the determination of scandium in synthetic sample of magnesium base with satisfactory results.
作者 周执明 俞玮
出处 《浙江工学院学报》 CAS 1991年第2期88-91,共4页
关键词 测定 5-BR-PADAP 分光光度法 Scandium 5-Br-PADAP Triton X-100 Chromogenic system Spectrophotometry