期刊文献+

Determination of Heavy Metals in Tobacco by ICP-MS and Analysis of Uncertainty 被引量:2

Determination of Heavy Metals in Tobacco by ICP-MS and Analysis of Uncertainty
下载PDF
导出
摘要 The research aims to set up the determination method of heavy metals in tobacco by ICP-MS and analyze its uncertainty. Microwave digest technique is used for decomposition of the tobacco samples. Bi,Sc,Ge and In are employed as internal standards to eliminate the interference of the matrix. A method is developed for simultaneous determination of Cr,Cu,As,Cd,Hg and Pb in tobacco from Yunnan Province by ICP-MS,and the measurement uncertainty is evaluated by metrological method. The test results indicate that in the content range of0- 1. 0 g / ml,the linearly dependent coefficient of six elements is 1. 0000,and the RSD achieves 1. 5%- 11%( n = 8). The elemental content in tobacco is as follows: Cr( 2. 92,0. 24) mg / kg,Cu( 3. 64,0. 24) mg / kg,As( 0. 467,0. 025) mg / kg,Cd( 3. 12,0. 15) mg / kg,Hg( 0. 035,0. 006) mg/kg,Pb( 4. 62,0. 36) mg/kg. The uncertainty of sample size,the constant volume of the sample solution can be neglected. It is concluded that the method is accurate,simple,sensitive and rapid. The research aims to set up the determination method of heavy metals in tobacco by ICP-MS and analyze its uncertainty. Microwave digest technique is used for decomposition of the tobacco samples. Bi,Sc,Ge and In are employed as internal standards to eliminate the interference of the matrix. A method is developed for simultaneous determination of Cr,Cu,As,Cd,Hg and Pb in tobacco from Yunnan Province by ICP-MS,and the measurement uncertainty is evaluated by metrological method. The test results indicate that in the content range of0- 1. 0 g / ml,the linearly dependent coefficient of six elements is 1. 0000,and the RSD achieves 1. 5%- 11%( n = 8). The elemental content in tobacco is as follows: Cr( 2. 92,0. 24) mg / kg,Cu( 3. 64,0. 24) mg / kg,As( 0. 467,0. 025) mg / kg,Cd( 3. 12,0. 15) mg / kg,Hg( 0. 035,0. 006) mg/kg,Pb( 4. 62,0. 36) mg/kg. The uncertainty of sample size,the constant volume of the sample solution can be neglected. It is concluded that the method is accurate,simple,sensitive and rapid.
出处 《Asian Agricultural Research》 2016年第10期51-54,共4页 亚洲农业研究(英文)
基金 Supported by Fund Project of Yunnan Provincial Department of Education(2013Y475) Science and Technology Project of State General Administration for Quality Supervision(2013QK071)
关键词 ICP-MS TOBACCO Heavy metals Microwave digestion Uncertainty measurement ICP-MS Tobacco Heavy metals Microwave digestion Uncertainty measurement
  • 相关文献

参考文献13

二级参考文献208

共引文献364

同被引文献38

引证文献2

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部