通过对过滤器滤芯和反渗透膜元外观与显微分析,判断出超滤和反渗透膜元内污染物为有机物,并结合能谱分析加以确认,找出了超滤和反渗透出力下降的原因,并提出了防范措施。
Through the analysis of the filter cartridge and reverse osmosis membrane element with the microscopic appearance,which determined the pollutants in ultra-filtration and reverse osmosis membrane element for organic matter,and combined with spectrum analysis to confirm,found out the reason of the ultra-filtration and reverse osmosis output decline,and put forward the preventive measures.
出处
《安徽电力》
2015年第2期52-54,共3页
Anhui Electric Power
关键词
发电厂
化学预脱盐系统
超滤
反渗透
保安过滤器
有机物
power plant
chemical pre-desalination system
ultra-filtration
reverse osmosis
security filter
organic matter