摘要
通过对平圩发电有限责任公司2号机组小汽轮机远方打闸后复位指示灯延时灭灯故障事件的阐述及原因分析,说明汽轮机油系统故障问题多数为管路系统及油质问题。
After remote of small steam turbine tripped in Pingwei power generation CO.,LTD No.2 units,the lighting-off delay fault of the reset lights was stated and reason analysis,and explained the most problems of steam turbine system which were piping system and oil problems.
出处
《安徽电力》
2015年第4期29-31,共3页
Anhui Electric Power
关键词
电磁阀
压力开关
危急遮断
脱扣
solenoid valve
pressure switch
emergency trip
tripping