期刊文献+

Development of RP-HPLC method for simultaneous determination of docetaxel and curcumin in rat plasma: Validation and stability 被引量:3

Development of RP-HPLC method for simultaneous determination of docetaxel and curcumin in rat plasma: Validation and stability
下载PDF
导出
摘要 The purpose of the present research was to develop a suitable, simple, precise, accurate,robust, and reproducible RP-HPLC method for a reliable simultaneous quantification of docetaxel(DTX) and curcumin(CCM) in rat plasma samples using paclitaxel(PTX) as an internal standard. The samples were assayed by the Agilent 1260 Infinity HPLC instrument using a Capcell Pak C8 column(4.6 mm × 150 mm, 5 μm) under isocratic conditions. The mobile phase consisted of acetonitrile and triple distilled water(40/60, v/v) with a flow rate of 1.0 ml/min. The eluent was monitored at 230 nm for simultaneous measurement of curcumin and docetaxel. The method was validated by determining system suitability, selectivity, sensitivity, linearity, inter-day and intra-day precision, accuracy, robustness, and stability in accordance with the guidelines of the United States Food and Drug Administration(FDA).The developed chromatographic method proved to be simple, precise, accurate, robust and reproducible. Moreover, the samples showed stability at room temperature over a period of 48 h. Thus, this method would be employed for routine simultaneous quantification of docetaxel and curcumin in rat plasma samples. The purpose of the present research was to develop a suitable, simple, precise, accurate,robust, and reproducible RP-HPLC method for a reliable simultaneous quantification of docetaxel(DTX) and curcumin(CCM) in rat plasma samples using paclitaxel(PTX) as an internal standard. The samples were assayed by the Agilent 1260 Infinity HPLC instrument using a Capcell Pak C8 column(4.6 mm × 150 mm, 5 μm) under isocratic conditions. The mobile phase consisted of acetonitrile and triple distilled water(40/60, v/v) with a flow rate of 1.0 ml/min. The eluent was monitored at 230 nm for simultaneous measurement of curcumin and docetaxel. The method was validated by determining system suitability, selectivity, sensitivity, linearity, inter-day and intra-day precision, accuracy, robustness, and stability in accordance with the guidelines of the United States Food and Drug Administration(FDA).The developed chromatographic method proved to be simple, precise, accurate, robust and reproducible. Moreover, the samples showed stability at room temperature over a period of 48 h. Thus, this method would be employed for routine simultaneous quantification of docetaxel and curcumin in rat plasma samples.
出处 《Asian Journal of Pharmaceutical Sciences》 SCIE CAS 2017年第1期105-113,共9页 亚洲药物制剂科学(英文)
基金 supported by the Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT and Future Planning (NRF-2015R1C1A1A01051698)
关键词 CURCUMIN DOCETAXEL HPLC Plasma-extraction SIMULTANEOUS determination VALIDATION Curcumin Docetaxel HPLC Plasma-extraction Simultaneous determination Validation
  • 相关文献

参考文献1

二级参考文献3

共引文献2

同被引文献23

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部